Use your email for login
Use your email for registration
Engineered for exceptional radial force and effective, long-term closure of Muscular Ventricular Septal Defects.
Email Enquiry
Biocompatible Nitinol wire mesh optimized for complex intra-cardiac profiles.
Excellent conformability designed to fit the thick muscular septal wall.
Long-waist design engineered to secure stable positioning across deep cavities.
Densely woven structure supports swift endothelization and rapid healing.
OCCLUNIX® Muscular Occluder is a self-expandable, double-disc device made from precise nitinol wire mesh, designed specifically for percutaneous transcatheter closure of muscular ventricular septal defects (VSD).
The frame of the disc provides a secure foundation for the native growth of tissue. The elongated central connecting waist is custom-engineered to match the width of thick muscular walls, while three built-in polyester fabric inserts assist in prompt, immediate defect occlusion.
Request Technical DatasheetSized with specialized length options matching thick ventricular septa.
Premium superelastic nitinol wire reduces systemic complication patterns.
Exhibits excellent retention parameters under demanding ventricular force.
Strategically placed radiopaque marker sets assure clear deployment visibility.
Woven polyester matrix layers prevent immediate residual leakage paths without compressing native vascular channels.
Thermo-elastic grid parameters maintain consistent radial expansion patterns within deep intra-cardiac spaces.
Left and Right disc arrays deploy evenly on both sides of the muscular septum to distribute retention loads safely.
Engineered specifically to span thick myocardial margins securely, preventing device shift under pressure.
| Sl No. | Product Code | Device Size / Waist Dia (D) mm | Left Disc Dia (D1) mm | Waist Length (L) mm | Right Disc Dia (D2) mm | Recommended Sheath Size |
|---|---|---|---|---|---|---|
| 1 | RCOM040909 | 4 | 9 | 7.0 | 9 | 6F |
| 2 | RCOM061111 | 6 | 11 | 7.0 | 11 | 7F |
| 3 | RCOM081313 | 8 | 13 | 7.0 | 13 | 8F |
| 4 | RCOM101515 | 10 | 15 | 7.0 | 15 | 9F |
| 5 | RCOM121717 | 12 | 17 | 7.0 | 17 | 10F |
| 6 | RCOM141919 | 14 | 19 | 7.0 | 19 | 10F |
| 7 | RCOM162121 | 16 | 21 | 7.0 | 21 | 12F |
| 8 | RCOM182323 | 18 | 23 | 7.0 | 23 | 12F |
Percutaneous transcatheter closure of clinically recognized Muscular Ventricular Septal Defects (VSD) or specific complex localized muscular wall anomalies.
Targeted size spans optimized to seal intricate muscular pathways while ensuring minimal systemic pressure variance.
4 mm – 18 mmManufactured inside tightly regulated spaces keeping consistency constant.
Advanced heat-treatment engineering steps back every nitinol mesh structure.
Developed to strictly line up alongside standard international quality criteria.
1st Main Rd, Metro Lay Out, Nayanda Halli, Bengaluru, Karnataka 560026